EasyManua.ls Logo

Skope ReFlex Upright - Page 29

Skope ReFlex Upright
61 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
29
SKOPE Reflex Upright Fridge, Freezer, Combo
Troubleshooting
Service Manual
• Product is too warm. • Frequent door opening. • Limit door openings.
• Recently loaded. • Allow time for the product
to cool down.
• Door not closing properly. • Check and clean door
gasket.
• Refrigeration cartridge
operating too hot.
• Excessive door opening
or refrigeration heat load.
• Ensure the cabinet has
good ventilation around
the refrigeration
cartridge.
• Ensure the cabinet is
within the maximum
operating conditions.
• Set point is to high. • Lower set point.
• Moisture build up on door
or exterior.
• High humidity. • Check ambient operating
temperature and
ventilation requirements,
and reposition cabinet if
necessary.
• Frequent door opening. • Limit door openings.
• Door not closing properly. • Check and clean door
gasket.
• Cabinet door does not
shut properly.
• Cabinet is on an uneven
surface.
• Level the cabinet.
• Door is obstructed. • Check shelves and
product.
• Warm cabinet
temperatures.
• Compressor operating for
long periods (more than 1
hour).
• Blocked condenser. • Clean the condenser.
• Poor ventilation around
refrigeration cartridge.
• Ensure the cabinet has
good ventilation around
the refrigeration
cartridge.
• Ensure the cabinet is
within the maximum
operating temperature.
• Refrigeration fault. • Swap cartridge and
service faulty cartridge as
required.

Table of Contents