32
Replacement Procedures
Service Manual
SKOPE Reflex Upright Fridge, Freezer, Combo
8 Replacement Procedures
Lighting
The cabinet is fitted with LED modular interior lights. Ensure the light is
replaced with the same light type. Fluorescent or LED tubes cannot be used
in place of LED modular lights.
The lighting is made up of three components which are replaceable:
LED modular light/s
Light power supply
Interior wiring loom
Lighting components are all non serviceable items. If a component is faulty,
it should be removed and a SKOPE OEM new replacement component
fitted.
Refer to the diagnostics table below to determine what component may be
at fault, and the procedures over the next few pages for component
replacement instructions.
Ensure the cabinet is isolated from the power supply before cleaning or
removing parts.
Lighting fault diagnostics
IMPORTANT
Replace the light with the same SKOPE OEM part.
DO NOT use alternative LED strip or tube lights, or fluorescent
tubes.
Problem Possible Cause Repair
No lights working.
Cabinet is dark.
Lights switched off.
Switch lights on at
electronic controller
faceplate (see page 9), or
the app.
Controller is in Energy
Saving mode.
Open the door to bring
the controller into Normal
mode.
Controller alarm.
Check controller for alarm
code.
Plug not connected
properly.
Check and clean light
supply plugs to and from
light power supply.
Light power supply fault.
Replace light power
supply.
Light component not
working.
Plug not connected
properly.
Check and clean plug
connection in cabinet.
Faulty light. Replace light.
Segment of light not
working.
Faulty light. Replace light.