Operation
69
Model MMV Rev. 10/11
4. Make sure the parking brake switch is ENGAGED.
5. Place the travel select lever in (N) NEUTRAL and move the neutral
lock lever to NEUTRAL LOCK position.
6. Turn the ignition switch to the START position to crank the starter.
IMPORTANT! DO NOT crank the starting motor continuously for more than
30 seconds. Stop cranking the starter and allow the starter to cool for 2
minutes before engaging the starter again.
7. As the engine starts, release the ignition switch to the RUN posi-
tion. Depress the accelerator pedal enough to provide a smooth
idle speed.
8. The engine oil pressure warning indicator light should go OFF
within five seconds after starting. If the light remains ON, turn the
ignition switch OFF immediately and check the oil level or change
to a lighter weight oil. Consult the engine manufacturer’s manual for
alternative oils for cold weather operation.