70
Model MMV Rev. 10/11
Operation
This vehicle is equipped with a 24 volt, negative ground electrical system.
The NATO slave receptacle (1) is located under the engine cover in front of
the transmission. Ensure that both the disabled and booster vehicle are
equipped with a NATO slave receptacle.
1. Connect the NATO slave cable to the booster vehicle NATO slave
receptacle.
2. Connect the other end of the NATO slave cable to the disabled
vehicle NATO slave receptacle.
3. Run the booster vehicle at a speed just above idle.
4. Follow the steps in “Normal Starting” on page 67.
5. After starting the disabled vehicle, return the booster vehicle to idle.
6. Remove the NATO slave cable from the disabled vehicle first and
then from the booster vehicle.
Slave Starting
WARNING: To avoid death or serious personal injury,
never slave start the vehicle with a frozen battery as it will
explode. Keep sparks, flames and lighted smoking materials away
from the battery. Lead acid batteries generate explosive gases
when charging. Wear safety glasses when working near batteries.