SEMI-AUTOMATIC
7
1 Introduction
1.1 Preamble
Thank you for choosing the defibrillator manufactured by A.M.I. Italia S.r.l. SMARTY Saver Plus model.
In order to use the device correctly, you must read this user manual carefully before use. This user manual contains the
instructions for the use of SMARTY Saver Plus in compliance with its functionality and purpose. For an error-free
operation, it is fundamental that you comply with the requirements of this manual, in order to guarantee the safety of
the patient, of the rescuer and that of third parties.
This manual forms an integral part of the defibrillator and must always be kept in close proximity to the defibrillator, so
that it may be easily consulted whenever needed.
Note: In order to guarantee the correct and fast traceability of the product and to receive information regarding all
implemented updates, the user is requested to register the device at the appropriate section of the AMI ITALIA
website www.amiitalia.com.
1.2 Use in conformity with the provisions
The SMARTY Saver Series devices can be used only if the conditions indicated in this user manual are complied with.
All uses that differ from the intended use shall be understood not to comply with the provisions and may cause
harm/damage to persons and/or property; in such case, A.M.I. Italia S.r.l. hereby declines all liability.
1.3 Warranty
The SMARTY Saver Series devices are under warranty for 5 (five)* years.
The non-rechargeable battery SMT-C14031 is under warranty for 3 (three)* years in Stand-by mode (with battery
activation tests, daily self-tests and without the AED being switched on).
This information refers to new batteries that are fully charged and kept at a temperature of 20°C and 45% humidity.
*For more information, please see paragraph 14 “Warranty contract for SMARTY Saver series defibrillators”
1.4 Exclusion of liability
Liability rights in case of harm/damage to persons or to property shall be excluded, if attributable to one of the causes below:
– Using the device for uses other than its intended use.
– Using and maintaining the device inappropriately.
– Using the device and/or its accessories when they are visibly or partially damaged.
– Failing to comply with the instructions of the user manual concerning the precautions, use, maintenance and
repair of the device.
– Using non-original accessories and spare parts and/or of accessories and spare parts that are not approved by
the manufacturer.
– Performing arbitrary operations, repairs or modifications of the device.
– Arbitrarily exceeding the performance limits.
– Failing to supervise the parts that are subject to wear and tear.
1.5 Instructions
SMARTY Saver Plus device may be used only if the patient:
– is unconscious and
– is not breathing and
– has no heartbeat
1.6 Counterindications
SMARTY Saver Plus device may not be used if the patient:
– is conscious or
– is breathing normally or
– has a heartbeat