41
EEWB334A
5-45
5-46
5-47
5-46a
29281
26
The OPTIMIZATION OP.9 screen (Fig. 5-45) is displayed.
Fig. 5-45 OPTIMIZATION “OP.9”
START is signalled on the screen.
Spin the wheel.
A measuring run is performed.
The screen OPTIMIZATION “OP.10”, outside (Fig.
5-46) or the screen OPTIMIZATION “OP.10”, inside
(Fig. 5-47) is displayed.
Reading H 0
Optimum condition has been achieved and cannot be
improved.
Continue as shown on screen BALANCING
(Fig. 5-51).
Reading H 2
a)
Wheel running conditions cannot be improved.
Press ESC or BALANCING (1,28, Fig.5-46a) to
quit Optimization.
b)
However, it is possible to readjust the tire relative to
the rim to obtain a quite considerable minimization of
balance weights (i.e. smaller weights) without having
an adverse effect on wheel running conditions.
Press MINIMIZATION (29, Fig.5-46a)