Troubleshooting
52
8.1 Trouble Shooting
Faults
SPI Fault
SCI Fault
CAN1 Fault
PV Config Fault
Inv EEPROM Fault
Relay Fault
Sample Fault
RCD Fault
Fan1 Fault
Fan2 Fault
Diagnosis and solution
SPI communication fault
Disconnect PV+ , PV- and battery, reconnect them.
Or seek help from us, if can not go back to normal state.
SCI communication fault
Disconnect PV+ , PV- and battery, reconnect them.
Or seek help from us, if can not go back to normal state.
CAN communication fault
Disconnect PV+ , PV- and battery, reconnect them.
Or seek help from us, if can not go back to normal state.
PV Connection Setting Fault
Resetting the PV connection
Or seek help from us, if can not go back to normal state.
Inverter EEPROM fault
Disconnect PV+ , PV- and battery, reconnect them.
Or seek help from us, if can not go back to normal state.
Relay Fault
Disconnect PV+ , PV- and battery, reconnect them.
Or seek help from us, if can not go back to normal state.
The detection circuit Fault
Disconnect PV+ , PV- and battery, reconnect them.
Or seek help from us, if can not go back to normal state.
Residual Current Device Fault
Check the impedance of DC input and AC output.
Disconnect PV+ , PV- and battery, reconnect them.
Or seek help from us, if can not go back to normal state.
Fan Device Fault
Disconnect PV+ , PV- and battery, reconnect them.
Check if the fan is stopped by dust or other foreign.
Or seek help from us, if can not go back to normal state.
This section contains information and procedures for solving possible problems
with the X-hybrid series inverters, and provides you with trouble shooting tips
to identify and solve most problems that could occur with the X-hybrid series
inverters.
This section will help you narrow down the source of any problems you may
encounter. Please read the following troubleshooting steps.
• Check the war
ning or fault messages on the System Control Panel or Fault
codes on the inverter information panel. If a message is displayed, record it
before doing anything further.
• Attempt the solution indicated in below table
.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolaX Power SK-TL3000 and is the answer not in the manual?

SolaX Power SK-TL3000 Specifications

General IconGeneral
BrandSolaX Power
ModelSK-TL3000
CategoryInverter
LanguageEnglish

Related product manuals