Troubleshooting
56
Faults
Diagnosis and solution
Mgr CAN Fault
Manager CAN Fault
• Turn off the PV, battery and grid , reconnect them.
• Or seek for help from us if can not back to normal.
C1 SPI Fault
C1 TZ Fault
C1 FAN Fault
C1 sample Fault
Charge can communication fault.
• Turn off the PV, battery and grid , reconnect them.
• Or seek for help from us if can not back to normal.
Charge over current detected by hardware.
• Turn off the PV, battery and grid , reconnect them.
• Or seek for help from us if can not back to normal.
Charge FAN fault.
• Check if the fan is blocked .
• Or seek for help from us if can not back to normal.
Charge sample fault.
• Turn off the PV, battery and grid , reconnect them.
• Or seek for help from us if can not back to normal.
If your inverter's information panel is not displaying a Fault light, check the
following list to make sure that the present state of the installation allows proper
operation of the unit.
8.2 Routine Maintenance
● Inverter
Inverters need to be checked every 12 months . (once per year)
Clean the housing with a dry cloth and check that there is no airflow obstruction.
Remove any dust build-up from the locations as indicated. Check the inverter
and the cables for visible external damage on regular basis.
Clean the airflow holes inside the housing, and cut off the power
from the inverter by decommissioning or by using a bypass switch.
Internal cleaning is only to be carried out by certified persons.
Contact your installer/dealer if you find any defects. Do not perform
any repair work by yourself.
WARNING!
• Is the inverter located in a clean, dry, and adequately ventilated place?
• Have the DC input breakers been opened?
• Are the cables adequately sized and short enough?
• Are the input and output connections and wiring in good condition?
• Are the configurations settings correct for your particular installation?
• Are the display panel and the communications cable properly connected
and undamaged?
Contact SolaX Customer Service for further assistance. Please be prepared to
describe details of your system installation and provide the model and serial
number of the unit.