EasyManuals Logo

Solcon MPS 3000 User Manual

Solcon MPS 3000
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #36 background imageLoading...
Page #36 background image
SET PAGE - MENUS
Page 36 of 67
Temperature Settings
Temperature
*** Settings ***
General Note:
Level 1 & 2 Fault
Display
Fault occurs when
temperature is above the set
parameter for more than a
fixed time period of 2
seconds
Description
RTD Type
Platinum 100
Ohm
Resistance Temperature Detector Type.
Range: Copper 10 Ohm, Platinum 100 Ohm, Nickel 120 Ohm
Sensor 7-10
Type
RTD
Type of sensors T7..T10. MPS3000 can be ordered with T7..T10
measurement circuits designed for Thermistors instead RTD.
Range: RTD, PTC Thermistor, NTC Thermistor
T1 Level 1
120 EC
RTD No. 1 level 1
Range: 0 - 250 EC. Increment: 1 EC
T1 Level 2
140 EC
RTD No. 1 level 2.
Range: 0 - 250 EC. Increment: 1 EC
T2 Level 1
120 EC
RTD No. 2 level 1
Range: 0 - 250 EC. Increment: 1 EC
T2 Level 2
140 EC
RTD No. 2 level 2
Range: 0 - 250 EC. Increment: 1 EC
T3 Level 1
120 EC
RTD No. 3 level 1
Range: 0 - 250 EC. Increment: 1 EC
T3 Level 2
140 EC
RTD No. 3 at level 2
Range: 0 - 250 EC. Increment: 1 EC
T4 Level 1
120 EC
RTD No. 4 level 1
Range: 0 - 250 EC. Increment: 1 EC
T4 Level 2
140 EC
RTD No. 4 level 2
Range: 0 - 250 EC. Increment: 1 EC
T5 Level 1
120 EC
RTD No. 5 level 1
Range: 0 - 250 EC. Increment: 1 EC
T5 Level 2
140 EC
RTD No. 5 level 2
Range: 0 - 250 EC. Increment: 1 EC
T6 Level 1
120 EC
RTD No. 6 level 1
Range: 0 - 250 EC. Increment: 1 EC
T6 Level 2
140 EC
RTD No. 6 level 2
Range: 0 - 250 EC. Increment: 1 EC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Solcon MPS 3000 and is the answer not in the manual?

Solcon MPS 3000 Specifications

General IconGeneral
BrandSolcon
ModelMPS 3000
CategoryPower Supply
LanguageEnglish

Related product manuals