DATA PAGE - MENUS
Page 55 of 67
DATA PAGE - MENUS
These menus are accessed by pushing the Data Page button.
Measured Data
Measured
*** Data ***
Display
Description
Vp1 Vp2 Vp3
277 277 277 V
Phase to Neutral voltages.
Range: 100 V - 12.7 KV.
VL12 VL23 VL31
480 480 480 V
Line to Line Voltages.
Range: 100 V - 25 KV.
I1 I2 I3
137 138 139 A
Line (motor) currents.
Range: 1 A - 24 KA.
Ground Current
0 Amp.
Ground current.
1 A - 2000A
Frequency
50.0 Hz
Power
97.5 KW
Mains frequency.
40Hz – 70Hz
Total motor power.
Range: 0 - 30MW.
Reactive Power
60.5 KVAR
Total motor reactive power
Range: 0 - 30 MVAR
Power Factor
0.89
Total (Average of three phases) motor power factor.
Range : 0.0 - 1.00
T1 T2 T3
110 111 109 °C
RTD 1 - 3 Temperature
Range: 0°C - 200°C
T4 T5 T6
110 111 109 °C
RTD 4 - 6 Temperature
Range: 0°C - 200°C
T7 T8 T9
70 68 ??? °C
RTD 7 -9 Temperature
Range: 0°C - 200°C Note: With Thermistors units are (1/10) KΩ
???: RTD means not connected
T10
??? °C
RTD 10 Temperature
Range: 0°C - 200°C Note: With Thermistors units are (1/10) KΩ
???: RTD means not connected
Analog Input # 1
0%
Analog Input 1 in % of full range.
Range: 0% - 100%
Analog Input # 2
0%
Analog Input 2 in % of full range.
Range: 0% - 100%
Analog Input # 3
0%
Analog Input 3 in % of full range.
Range: 0% - 100%
Analog Input # 4
0%
Analog Input 4 in % of full range.
Range: 0% - 100%