Torque
Cover screws 1.5-1.7 ft.lbs
Ground screws (Cover)
4.4-6.0 ft.lbs
AC terminals
11-15 ft.lbs
Ground screws (Internal)
11-15 ft.lbs
Figure 10.1 For all models of inverter
Comments:
A thermal sensor inside the inverter is calibrated to determine ambient temperature.
All inverters will begin a sloped derate at 50°C ending at 60% output power at 60°C.
Temperatures above 60C or below -25C will de-rate to 0% output power. Inverter will
also de-rate output power when a fan is blocked or non-operational.
In this case, a warning message will appear on the front panel LCD.
10. Appendix
User Manual
75
10.1 Temperature Derating

Table of Contents

Other manuals for SOLIS S6 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SOLIS S6 Series and is the answer not in the manual?

SOLIS S6 Series Specifications

General IconGeneral
Number of MPPTs2
THDi<3%
DC SwitchYes
Max. AC Output Power6000W
Rated AC Output Power6000W
Max. AC Apparent Power6000VA
Rated Grid Voltage230V
Grid Voltage Range180V-280V
Rated Grid Frequency50Hz/60Hz
Grid Frequency Range45-55Hz / 55-65Hz
ProtectionDC Reverse-Polarity Protection, AC Short-Circuit Protection
Operating Temperature Range-25°C to 60°C
CoolingNatural Cooling
CommunicationWiFi/GPRS