39
LED Colour Flash/illumination
sequences
Possible cause Corrective action
SAFETY
Red
Photocell interrupted/defective Remove obstacle
Repair/replace photocell
Safety contact strip triggered/
defective
Remove obstacle
Remove obstacle
Repair/replace safety contact
strip
Programmed motor run time
exceeded
Check that the roller door runs
smoothly: repair/replace if
necessary
Check limit switch of tubular
motor: repair/replace if necessary
Check tubular motor: repair/
replace if necessary
Locking mechanism triggered • Repair/replace locking
mechanism
Hardware error on circuit board Replace control unit
BUZZER
Red
On
Buzzer not active/defective Connect/replace Buzzer
if necessary
O󰀨
Buzzer active If necessary, check settings
in SOMlink