6-11
EEPROM DATA 3 -– DL -–
CD LCD SL L0 L1
Analog FRSW xx xx xx xx xx
PLL Dac Gain xx xx xx xx xx
Mirror Time xx xx xx xx xx
_ THR A&L xx xx xx/xx xx xx
UP : PREV Data
DOWN : First Data
CLEAR: DefaultSet page.3/3
On this screen, current servo adjusted data stored in the EEPROM
are displayed. The adjusted data are initialized by pressing the
[CLEAR] key, but be careful that they are not recoverable after
initialization.
Before clearing the adjusted data, make a note of the set data. This
screen will also appear if [0] All is selected in the Drive Auto
Adjustment. In this case, default setting cannot be made.
Data of “THR A & L” on page 3/3 can not be changed if default
set is done.
6-6. MECHA AGING
### Mecha Aging ###
Press OPEN key
Abort: STOP key
On the Test Mode Menu screen, selecting [3] executes the aging
of mechanism. First, open the tray and load a disc. Press
the H key, and the aging will start. During aging, the repeat cycle
is displayed. Aging can be aborted at any time by pressing
the x key. After the operation has stopped, unload the disc and
press again the x key or the [ RETURN] key to return to the
Test Mode Menu.
6-7. EMERGENCY HISTORY
### EMG. History ###
Laser Hours CD xxhxxm
DVD xxhxxm
1. 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
2. 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
Select: 1-9 Scroll: UP/DOWN
(1: Last EMG.) Exit: RETURN
On the Test Mode Menu screen, selecting [4] displays the infor-
mation such as servo emergency history. The history information
from last 1 up to 10 can be scrolled with
key or
key. Also,
specific information can be displayed by directly entering that
number with ten keys.
The upper two lines display the laser ON total hours. Data below
minutes are omitted.
Clearing History Information
Clearing laser hours
Press [DISPLAY] and [CLEAR] keys in this order.
Both CD and DVD data are cleared.
Clearing emergency history
Press [TOP MENU] and [CLEAR] keys in this order.
Initializing set up data
Press [MENU] and [CLEAR] keys in this order.
The data have been initialized when “Set Up Initialized” mes-
sage is displayed. The EMG. History screen will be restored
soon.