DPU/DO - Page 29 - REV. 5/25/00
--------------------------------
**Set Parameters For Unit - 1 **
---> HEAVY CARRIAGE
*(0) No
(1) Yes
Use < > to Select Option
Use <NUMBER> to Set Option
<SAVE> to Save <ESCAPE> to Exit
--------------------------------
-- Heavy Carriage Parameter Screen --
When a carriage is very heavily loaded, the motor must react more quickly to maintain a constant
speed over the distance traveled. If this parameter is set to YES, the motor on the carriage will
react more quickly to conditions that vary motor speed over the course of travel. This parameter
should be set to NO for most applications. The large check mark indicates that not all carriages
will necessarily be set the same for this parameter.
--------------------------------
**Set Parameters For Unit - 1 **
--> MOTOR CREEP TIMEOUT (sec.)
Enter Value <10-60> - 10_
Use < > to Select Option
Value <ENTER> to Set Option
<SAVE> to Save <ESCAPE> to Exit
--------------------------------
-- Motor Creep Timeout Parameter Screen --
This parameter screen allows the user to set the amount of time the motor can continue running
at its slowest possible speed. After creeping for the entered amount of time, in seconds, the
motor will automatically shut down. This prevents damage from misadjusted or malfunctioning
limit switches. Any value from 10 to 60 seconds can be entered for this parameter. See page 23
for details regarding entry of a numeric value.