DPU/DO - Page 49 - REV. 5/25/00
POWER PRO PARAMETER SCREENS
--------------------------------
**Set Parameters For Unit - 1 **
--> MOTOR CREEP TIMEOUT (sec.)
Enter Value <10-31> - 10_
Use < > to Select Option
Value <ENTER> to Set Option
<SAVE> to Save <ESCAPE> to Exit
--------------------------------
-- Motor Creep Timeout Parameter Screen --
This parameter screen allows the user to set the amount of time the motor can continue running
at its slowest possible speed. After creeping for the entered amount of time, in seconds, the
motor will automatically shut down. This prevents damage from miss-adjusted or
malfunctioning limit switches. Any value from 10 to 31 seconds can be entered for this
parameter. See page 23 for details regarding entry of a numeric value.
--------------------------------
**Set Parameters For Unit - 1 **
--> AUTO STOP TIMEOUT (sec.)
Enter Value <15-63> - 30_
Use < > to Select Option
Value <ENTER> to Set Option
<SAVE> to Save <ESCAPE> to Exit
--------------------------------
-- Auto Stop Timeout Parameter Screen --
This parameter screen allows the user to set the amount of time the motor can continue running
in an effort to complete the movement cycle. After running for the entered amount of time, in
seconds, the motor will shut down. This prevents damage from misadjusted or malfunctioning
limit switches. Any value from 15 to 63 seconds can be entered for this parameter. See page 23
for details regarding entry of a numeric value.