DPU/DO - Page 44 - REV. 5/25/00
POWER PRO PARAMETER SCREENS
--------------------------------
**Set Parameters For Unit - 1 **
---> PHOTO SWEEP TYPE
*(0) Photo Sweep II
(1) Photo Sweep I
Use < > to Select Option
Use <NUMBER> to Set Option
<SAVE> to Save <ESCAPE> to Exit
--------------------------------
-- Photo Sweep Type Selection Parameter Screen --
Most systems will be configured with Photo Sweep II, however when ambient lighting may cause
problems, Photo Sweep I can be provided.
--------------------------------
**Set Parameters For Unit - 1 **
---> LEFT PHOTO SWEEP
*(0) Active
(1) Disabled (JP4 also)
Use < > to Select Option
Use <NUMBER> to Set Option
<SAVE> to Save <ESCAPE> to Exit
--------------------------------
-- Left Photo Sweep Enable Parameter Screen --
If the carriage has mechanical sweep or shares a sweep with the adjacent carriage the photo
sweep needs to be disabled. It also requires a jumper on the JP4 header on the control board.
--------------------------------
**Set Parameters For Unit - 1 **
---> RIGHT PHOTO SWEEP
*(0) Active
(1) Disabled (JP4 also)
Use < > to Select Option
Use <NUMBER> to Set Option
<SAVE> to Save <ESCAPE> to Exit
--------------------------------
-- Right Photo Sweep Enable Parameter Screen --
If the carriage has mechanical sweep or shares a sweep with the adjacent carriage the photo
sweep needs to be disabled. It also requires a jumper on the JP4 header on the control board.