Component Testing Procedures
Fault Codes: F06
. Cycle Selector Test
Test Points Reading
CND to Selector 1 to 11 0 ohms
CND to Selector 2 to 10 0 ohms
CND to Selector 3 to 9 0 ohms
CND to Selector 4 to 8 0 ohms
CND to Selector 5 to 7 0 ohms
CND to Selector 6 to 6 0 ohms
CND to Selector 8 to 4 0 ohms
CND to Selector 10 to 2 0 ohms
Cycle Selector Test Points are located on the CND Connector and on the Cycle Selector. The CND Connector is located
on the Module Board (See “Connector Locations on the Module Board”). The Cycle Selector can be accessed once the
washer-dryer top is removed (See “Component Access Locations”).