ELECTRICAL
CONNECTION
INSTRUCTIONS
7.
ELECTRICAL
CONNECTION
INSTRUCTIONS
7.1
Wiring
Rules
and
Warnings
WARNING:
All
aspects
of the installation
must
conform
with
the
requirements
of
the
Standards
Australia (within
Australia)
Wiring
Rules
as
well
as
your
local
electrical
and
building
codes
and
regulations
and
any
other
applicable
requirements
and
conditions
of your
Local
Power
Supply
Authority.
A
licensed
electrician
must
perform
the
electrical work
when
installing
this
appliance.
The
supply
cable
and
fuse rating
must
be
suitable
for
the appliance.
WARNING:
To
avoid mains
borne
interference,
this
appliance
must
be
installed
individually
on
a
separate
and
distinct
final
sub-circuit.
NOTE:
To
the
Electrician
-
please
ensure
sufficient
supply
cable
is
provided
to
allow
the appliance
to
be
removed
from
the
cavity
should
any
servicing
be
necessary.
This
will
also
allow
easy
connection
of
the
supply.
7.2
Electrical
Loads
MAIN
OVEN
UEO
DEO UES
Oven
(Max.)
3800
W
3800
W
4200W
Grill
2700
W
2700
W
3500W
Oven
Fan
and
Light
100W
100
W
100W
SECONDARY
OVEN
Oven
-2400
W-
Grill
-2700
W-
Oven
Light
-
30
W-
Total
Rating
3.9 kW
6.63
kW
4.3
kW
When
connected
to
a
subcircuit
protected
by
a
circuit
breaker,
the
current
drawn
by
an
oven
may
cause
the
circuit
breaker
to
trip
in
some
cases.
It
is
recommended
that
the
following installation
procedures
are
used.