45GS 461
: Press short-circuit wire (1) into
the guides (arrows)
: Press ground wire (2) into the
guides (arrows)
Route wires parallel so that they do
not cross.
2411RA062 TG
1
2411RA063 TG
2
Crimped side of the blade
receptacle (1) must face the switch
shaft bearing.
: Push blade receptacle (1) of
ground wire (4) onto the contact
spring (2)
: Push in short-circuit wire (3) and
ground wire (4) between fin
(arrow) and housing wall
– Short-circuit wire (3) must be
routed below the ground wire (4)
– Install switch shaft, b 9.1.1
: Check correct functioning
– The eyelet (1) of the short-
circuit wire must touch the
contact spring (arrow) in position
"0"
2411RA064 TG
1
2
3
4
2411RA119 TG
1
3443RA224 TG
1 2
: Push grommet (1) onto wiring
harness (2)
– Install tank housing, b 10.8.3
: Push fuel suction hose (1) into
the guide (arrow) and press
between the wires and the
collar (2) of the intake elbow
mount – fuel suction hose is
secured
3443RA225 TG
1 2