Chapter 6 Diagnostics, Monitoring, and Troubleshooting 177
To view POST and diagnostic error messages in the local system console, you need
to connect an alphanumeric terminal or graphics console, or establish a tip
connection to another Sun system. For more information, see:
■ “How to Attach an Alphanumeric Terminal” on page 38
■ “How to Configure a Local Graphics Console” on page 39
■ “How to Set Up a tip Connection” on page 180
You must also verify baud rates between a system and a monitor or a system and a
terminal when using a tip connection. See:
■ “How to Verify the Baud Rate” on page 182
After RSC software is installed, you can redirect the system console output from the
server serial port A to RSC and view the POST and diagnostic error messages using
an RSC account. After this redirection, the local system console is not available. For
more information about redirecting a console after the RSC software is installed, see
your Sun Fire 280R Server Owner’s Guide.
You can choose to run an abbreviated POST with concise error and status reporting
or run an extensive POST with more detailed messages. For more information, see:
■ “How to Set the Diagnostics Level” on page 183
What to Do
Ensure that the front panel keyswitch is in the Power-On/Off position. For
descriptions of the keyswitch settings, see “Keyswitch Settings” on page 3.
You can initialize POST one of two ways:
■ By setting the diag-switch? to true and the diag-level to max, min,or
menus, followed by power cycling the system unit
■ By pressing the keyboard Stop-D (Stop-Shift-d) keys while power is applied to
the system unit, or by setting the keyswitch to the Diagnostics position and
pressing the Power button
To set the diag-switch? to true and power cycle the system unit:
1. When the ok prompt is displayed, type the following command:
2. After a few seconds, press the Power button on the system once.
The keyswitch must be set to the Power-On/Off position.
The system runs the POST diagnostics. POST displays status and error messages in
the system console.
ok setenv diag-switch? true