4 Mechanical Mounting User Manual
20
Type
Tool
crimping tool
RJ45 crimping
tool
Wire stripper
Hydraulic pliers
Other auxiliary tools that may be used
4.4 Moving the Inverter
Move the inverter to the specified position before installation. The inverter can
be moved manually or via a hoist.
4.4.1 Manual Transport
Lift and move the inverter to the destination by using the side handles and
bottom handles.
Inappropriate moving operation may cause personal injury!
It is recommended that at least two installers carry the inverter together
and wear protective equipment such as smash-proof shoes and gloves.
Always beware of the gravity center of the inverter and avoid tipping.
The ground surface on which the inverter is to be placed should be
covered with a sponge pad, foam cushion or the like to prevent the
inverter bottom from scratches.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sungrow SG33CX and is the answer not in the manual?

Sungrow SG33CX Specifications

General IconGeneral
ModelSG33CX
ManufacturerSungrow
Rated Power33 kW
Max DC Voltage1100 V
Max Efficiency98.7%
Start Voltage200 V
Total Harmonic Distortion< 3%
Power Factor at Rated Power1
DC Connection TypeMC4
Allowable Relative Humidity Range0 - 100%
Operating Altitude4000 m
MPPT Voltage Range200 V - 1000 V
AC Voltage Range310 V - 480 V
Rated Grid Frequency50 Hz / 60 Hz
Adjustable Power Factor Range0.8 leading to 0.8 lagging
Operating Ambient Temperature Range-25 °C ... +60 °C
CommunicationRS485