7 iSolarCloud APP User Manual
58
The username is user”, the initial password is "pw1111" which
should be changed for the consideration of account security.
To set inverter parameters related to grid protection and grid
support, contact SUNGROW to obtain the advanced account and
corresponding password.
Step 4 If the inverter is not initialized, you will enter the quick setting screen of
initialize protection parameter. After finishing setting on the quick setting
screen, click and the device will be initialized. The APP will send
start instructions and the device will start and operate.
Set according to local standards
Fig. 7-4 Initialization protection parameter
Reset the protection parameters if the country setting is incorrect.
Otherwise, fault may occur.
Step 5 If the inverter is initialized, the APP automatically turns to its home page.
7.5 Home page
After login, the home page is as follows:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sungrow SG33CX and is the answer not in the manual?

Sungrow SG33CX Specifications

General IconGeneral
ModelSG33CX
ManufacturerSungrow
Rated Power33 kW
Max DC Voltage1100 V
Max Efficiency98.7%
Start Voltage200 V
Total Harmonic Distortion< 3%
Power Factor at Rated Power1
DC Connection TypeMC4
Allowable Relative Humidity Range0 - 100%
Operating Altitude4000 m
MPPT Voltage Range200 V - 1000 V
AC Voltage Range310 V - 480 V
Rated Grid Frequency50 Hz / 60 Hz
Adjustable Power Factor Range0.8 leading to 0.8 lagging
Operating Ambient Temperature Range-25 °C ... +60 °C
CommunicationRS485