7 iSolarCloud APP User Manual
60
Tab. 7-2 Description of inverter state
After being energized, inverter tracks the PV arrays’ maximum
power point (MPP) and converts the DC power into AC power.
This is the normal operation mode.
Inverter will stop operation by manually “stop” via app. In this
way, inverter internal DSP stops. To restart the inverter,
manually start via app.
Inverter enters standby mode when DC side input is
insufficient. In this mode inverter will wait within the standby
duration.
The inverter is in the initial power-on standby state
The inverter is initializing and synchronizing with the grid.
Warning information is detected.
The inverter derates actively due to environmental factors such
as temperature or altitude
The inverter runs according to the scheduling instructions
received from the monitoring background
If a fault occurs, inverter will automatically stop operation, and
disconnect the AC relay. The fault information will be displayed
in the app. Once the fault is removed in recovery time, inverter
will automatically resume running.
Tab. 7-3 Description of PID function state
The inverters perform PID recovery actively.
The inverter is suppressing the PID effect.
It is detected that the ISO impedance is abnormal or the PID
function cannot work normally after the PID function enabled.
If the inverter is running abnormally, the alarm or fault icon
will be
displayed in the lower right corner of the inverter icon in power flow chart. The
user can tap this icon to enter the alarm or fault screen to view detailed
information and corrective measures.
7.6 Running Information
Tap " " on the navigation bar to enter the running information screen, as
shown in the following figure.