EasyManua.ls Logo

Sungrow SG33CX - Page 92

Sungrow SG33CX
95 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10 Appendix User Manual
82
Parameters
SG33CX
SG40CX
SG50CX
Nominal AC voltage
3 / N / PE230 / 400V
AC voltage range
312~528V
Nominal grid
frequency/Grid
frequency range
50Hz / 45~55Hz60Hz / 55~65Hz
Total harmonic distortion
(THD)
< 3 % (at nominal power)
DC current injection
<0.5%In
Power factor
>0.99
Adjustable power factor
0.8 leading 0.8 lagging
Feed-in phases /
Connection phases
3/3
Efficiency
Max. efficiency /
European efficiency
98.6% / 98.3%
98.6% / 98.3%
98.7% / 98.4%
Protection
DC reverse connection
protection
Yes
AC short-circuit
protection
Yes
Leakage current
protection
Yes
Grid monitoring
Yes
DC switch / AC switch
Yes / No
PV string current
monitoring
Yes
Q at night
Yes
PID recovery function
Optional
Overvoltage protection
DC Type II / AC Type II
General Data
Dimensions (W*H*D)
702 × 595 ×
310mm
782 × 645 ×
310mm
782 × 645 ×
310mm
Weight
50kg
58kg
62kg
Isolation method
Transformerless
Degree of protection
IP66
Night power
consumption
2 W
Operating ambient
temperature range
-30 to 60 (> 45 derating)
Allowable relative
humidity range
(non-condensing)
0 - 100%
Cooling method
Smart forced air cooling
Max. operating altitude
4000 m (> 3000 m derating)
Display
LED, Bluetooth + APP
Communication
RS485/ Wi-Fi(optional)/Ethernet(optional)