Make a setting based on the check points below to ensure proper operation of the top thread trimming device when the top
thread trimming device is installed.
Make the setting as below depending on the program version of the controller.
Modification of the sequence of Parameter B-55
Using the external program unit
Use and buttons when changing the value of sequence.
Use and buttons to move to the next sequence.
Program version
1
2
S-III version "11" or above
S-IV version "7" or above
Lower than S-III version "11”
Lower than S-IV version "7"
Set the value of Parameter A-73 at "1"
Modify the trimming sequence of Parameter B-55.
Setting
Move to B-55Parameter B GroupInitial Screen
POWER ON + +
⇨⇨⇨
80[ms]Lapsed Time: Unit-1[ms]
T/T Sol. ON
Sequence Start
⇨⇨⇨⇨
W/P Sol. ON
66[ms]Lapsed Time: Unit-1[ms]
T/T Sol. OFF
⇨⇨⇨⇨
Sequence End
W/P Sol. OFF
0[ms]
Lapsed Time: Unit-1[ms]
⇨⇨⇨⇨
Sequence Save
⇨