5-6 Publication: 0028607
WATER RECYCLING SYSTEM
5
9. Maintain a one-half to three-quarters fluid level in the
debris body by monitoring the debris level on the
front control panel HMI home screen.
While jetting the sewer, perform the following:
Close the vent door to increase the fluid level.
Open the vent door to decrease the fluid level
when the debris level turns red.
10. If at any point there is not enough water available in
the debris body to continue recycling, the system will
automatically switch back to using fresh water from
the fresh water tanks and display a CONSUMING
Fresh Water message (10) on the front control panel
HMI screen.
Figure 5-9
11. The front control panel HMI screen will display a
warning message if any filters need cleaning.
Filter Maintenance
Y-Strainer Cleaning
The Y-strainer acts as a last-chance filter for larger
particles and will filter some amounts of lint and fibrous
materials. The stainless steel filter element will need to
be removed and cleaned when prompted by the front
control panel HMI screen (1) or at the end of every
workday. Make sure the truck is in road mode before
proceeding.
Figure 5-10
1. Turn the water supply valve (2) at the front of the
debris body to the off position.
Figure 5-11
ok
10
ok
1
2

Table of Contents