Sutron Corporation Satlink Operations & Maintenance Manual, Rev 8.04.2 11/3/2016 pg. 139
15.1.2.1. Pseudobinary B Scheduled Example
Here is a transmission with three active measurements; each one is set to include two readings:
B1@@Gt@Gs@Sx@Sr@@i@@iEXTLBAAODAXe@R@A
Decoding the message
Denotes Pseudobinary B format
(no formatting is done by Satlink)
Battery voltage (12*0.234+10.6 )
Lat 39o 1' 15" Long 77o 24' 37"
15.2. Pseudobinary C Data Format
This format is based on the pseudobinary B format. It uses slightly more bandwidth than the B
format, but it is self-descriptive. It is used when the user selects Pseudobinary C as the choice for
Tx Format.
BLOCK-IDENTIFIER is always sent as C to indicate that this is the
pseudobinary C format.
GROUP-ID can be 1 to indicate a scheduled transmission, 2
meaning an alarm transmission, 3 indicating a forced
transmission, and 4 indicating a retransmission.
This byte is always a + and it is used to denote the start of
measurement data.
This is encoded 6 bit binary encoded (see below) number which,
when translated, tells the measurement index. Satlink assigns a
measurement index (starting with 1 and ending with 16) to each
user setup sensor.
This 2 byte encoded 6 bit binary encoded (see below) number
represents the Julian day of the year. The day tells when the
most recent (first) sensor reading of this measurement was
made.