Sutron Corporation Satlink Operations & Maintenance Manual, Rev 8.04.2 11/3/2016 pg. 29
Steinhart((10000)*X/(vref-X), A, B, C) (see table below for A, B, C)
Note: The 10000 is the reference resistor value in ohms.
Slope: 1.8; Offset: 32 to convert to Fahrenheit.
44036
5600-0025
5600-0030
Campbell Scientific’s CS205 & CS107 temperature probe requires different wiring than the
above since it has a reference resistor built into the probe. The wires are connected as indicated
below on the left and the equation will use the built in template for CS205/107. The image on
the right indicates the probe’s internal wiring for reference.
Jumper C+ to Vref
Purple (AG) ----------------- C+
Red (HI) ---------------------- C-
Black (EX) -------------------- AGND
Clear (G) --------------------- Earth Ground
4.18. Connecting Thermocouples
Thermocouples connect to SL3 to the C, D or E channels as shown below.