5. Removal & Installation of Engine
5-4
Remove AC generator and crankshaft position sensor
coupler.
Remove the start motor wire from the start relay.
Remove O
2
sensor wire coupler.
Start engine for the pipeline to be exhausted within the
residual pressure, the engine flameout, relaxing fuel
tube folder, open for fuel tube.
Caution
Demolition for the pipeline will be required for
residual pressure in the pipeline to divest, or use
the folder surrounds the tubing to prevent petrol
splash.
Start
motor
wire
O
2
sensor coupler
Fuel tube