96 XLi IEEE 1588 Clock
997-01510-03, Rev. C, 12/12/2006
SSSSSSSSSSSS SSSSSSSSSS SSSSSSS S SSS S SSSSS S
1
where:
The XLi responds:
ENTER NEW USER PASSWORD:
When you enter the new password, the XLi responds:
CONFIRM NEW USER PASSWORD:
Enter the same new password again, to confirm the spelling. If the same new password has been
entered twice, The XLi responds:
OK<CR><LF>
In this case, the new password will be used for the next login. However, if the new password is entered
differently the second time, The XLi responds:
ERROR: PASSWORDS DO NOT MATCH. NEW PASSWORD REJECTED.
F100 PI – PING
Use function F100 PI to ping a remote host to see if it is reachable. If no IP Address is provided, F100 PI
uses the XLi’s own IP Address, and tests whether the XLi’s network port has a good network connection.
To ping a known host, enter:
F100 PI<S><IP Address><CR>
For example:
F100 PI 206.254.000.021<CR>
The unit responds (example):
PING 206.254.000.021: REMOTE HOST FOUND.<CR><LF>
or
PING 206.254.000.021 : REMOTE HOST NOT FOUND.<CR><LF>
F
= ASCII character F
100 = unit function number
<S> = space
P = specify Password command
<CR> = input line terminator

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom XLi IEEE 1588 and is the answer not in the manual?

Symmetricom XLi IEEE 1588 Specifications

General IconGeneral
BrandSymmetricom
ModelXLi IEEE 1588
CategoryClock
LanguageEnglish

Related product manuals