132 XLi IEEE 1588 Clock
997-01510-03, Rev. C, 12/12/2006
SSSSSSSSSSSS SSSSSSSSSS SSSSSSS S SSS S SSSSS S
1
Response (one of the following lines):
OK - The PTP Option Card has been initialized to user entered values
Configuring the PTP Reference Clock Settings
To review the PTP reference clock configuration settings with respect to Master/Slave and reference
clock Primary/Secondary/Standby settings, use the following format:
F131 B<N> C<CR>
For example, enter:
F131 B4 C
Response (example):
F131 B4 C SLAVE PRI<CR><LF>
To change the settings, use the following format:
F131 B<N><SP>C<SP><MS><SP><CONFIG>
where:
For example, enter:
F131 B4 C SLAVE PRI
Response (one of the following lines):
OK - Ref Clock Configuration has been received and applied by the PTP Option Card
Note: The PTP reference clock configuration settings are saved in XLi NVRAM so they can be used to
initialize the PTP option card with Master/Slave and Pri/Sec/Stby selections at XLi power-up.
F = ASCII character F
131 = unit function number
<SP> = space
B = ASCII letter to denote Option Bay number follows
<N> = Option Bay Number, 1 through 4.
C = specify PTP Configuration command
<MS> = MASTER or SLAVE (Factory Default is MASTER)
<CONFIG> = PRI, SEC or STBY, which must be entered if the <MS> is SLAVE.
If the <MS> is MASTER, this field is not applicable.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom XLi IEEE 1588 and is the answer not in the manual?

Symmetricom XLi IEEE 1588 Specifications

General IconGeneral
BrandSymmetricom
ModelXLi IEEE 1588
CategoryClock
LanguageEnglish

Related product manuals