68 XLi IEEE 1588 Clock
997-01510-03, Rev. C, 12/12/2006
SSSSSSSSSSSS SSSSSSSSSS SSSSSSS S SSS S SSSSS S
1
where:
For example, enter:
F71<CR>
XLi responds:
F71 PHASE=-5.678E-09 s OFFSET=-1.986E-07 DRIFT= 6.013E-08/DAY DAC=24567<CR><LF>
F72 – Fault Status
Use function F72 to display the fault status of the clock.
Clock PLL – Locked or unlocked
Clock Status – Unlocked or locked plus one of the following reference types:
- GPS Primary receiver
- GPS Secondary receiver
- PTP Primary (when configured as a PTP slave)
- PTP Secondary (when configured as a PTP slave)
- (IRIG-A, IRIG-B, NASA 36 not supported)
Primary power supply – OK or failed
Secondary power supply – OK or failed
Rubidium oscillator (if installed) – OK or fault
Command Line
To display the status of the fault detectors, enter:
F = ASCII string indicating function F71
<S> = ASCII space character one or more.
<MULT> = multiplier, 4 digits with decimal point.
E = ASCII character E for exponent.
s = ASCII character s for seconds abbreviation
<SIGN> = - for negative or <S> for positive.
<EXP> = 2 digit exponent.
/DAY = ASCII characters, units of Drift Rate
<INT> = integer, 5 digits
<CR> = carriage return.
<LF> = line feed.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom XLi IEEE 1588 and is the answer not in the manual?

Symmetricom XLi IEEE 1588 Specifications

General IconGeneral
BrandSymmetricom
ModelXLi IEEE 1588
CategoryClock
LanguageEnglish

Related product manuals