82 XLi IEEE 1588 Clock
997-01510-03, Rev. C, 12/12/2006
SSSSSSSSSSSS SSSSSSSSSS SSSSSSS S SSS S SSSSS S
1
F100 EA – Ethernet Address
Use function F100 EA to display the Ethernet Address (MAC Address) (Note: An Ethernet or MAC
Address is not the same thing as an IP Address), a fixed, six-byte, hexadecimal value specific to the
unit’s standard network port. The first three bytes are registered to Symmetricom Inc.; the last three
bytes are the hex value identifying the network port.
To display the Ethernet address of the unit standard network port, enter:
F100 EA<CR>
The XLi responds:
F100 EA:00-A0-69-xx-xx-xx<CR><LF>
where “00-A0-69” is the portion of the address assigned to the manufacturer, and “xx-xx-xx” is unit’s
unique address (in hexadecimal).
An example of the response is:
F100 EA:00-A0-69-99-00-37
Attempts to set this field will be rejected with a syntax error message.
F100 IP – IP Address
Use function F100 IP to display or change the unit’s IP Address.
Use the following format to display the IP address:
F100<S>IP<CR>
Use the following format to set the IP address and restart the unit, enter:
F100<S>IP<S><nnn.nnn.nnn.nnn><CR>
where:
F = ASCII character F
100 = unit function number
<S> = space
IP = specify IP command
<nnn.nnn.nnn.nnn> = dotted decimal address (0 to 255)
<CR> = input line terminator

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom XLi IEEE 1588 and is the answer not in the manual?

Symmetricom XLi IEEE 1588 Specifications

General IconGeneral
BrandSymmetricom
ModelXLi IEEE 1588
CategoryClock
LanguageEnglish

Related product manuals