126 XLi IEEE 1588 Clock
997-01510-03, Rev. C, 12/12/2006
SSSSSSSSSSSS SSSSSSSSSS SSSSSSS S SSS S SSSSS S
1
Response (example):
F131 B4 IP:206.54.47.21 SM:255.255.255.0 G:206.54.47.1 (STATIC)<CR><LF>
Set the IP Address
To get the IP address, enter:
F131 B<N> IP
For example, enter:
F131 B4 IP
Response (example):
F131 B4 IP:206.54.47.21
To set the IP address, enter:
F131 B<N><SP>IP<SP>nnn.nnn.nnn.nnn
where:
For example, enter:
F131 B4 IP 206.54.47.21
Response (one of the following lines):
OK - The IP Address has been received and applied by the PTP Option Card<CR><LF>
Set the Subnet Mask
To get the Subnet Mask, enter:
F131 B<N> SM
To set the Subnet Mask, enter:
F = ASCII character F
131 = unit function number
<SP> = space
B = ASCII letter to denote Option Bay number follows
<N> = Option Bay Number, 1 through 4.
IP = specify Internet Protocol command
nnn.nnn.nnn.nnn = dotted decimal address