XLi IEEE 1588 Clock 131
997-01510-03, Rev. C, 12/12/2006
2
5
1
SSSSSSSSSSSS SSSSSSSSSS SSSSSSS S SSS S SSSSS S
where:
For example, enter:
F131 B4 SDN _ALT1
Response (example):
>f131 b4 sdn _ALT1
OK - The Subdomain Name been received and applied by the PTP Option Card
Reset the PTP Parameters to the Factory Default settings
To reset the PTP parameters to the factory default settings, use the following format:
F131 B<N> RFD<CR>
For example, enter:
F131 B4 RFD
Response (one of the following lines):
OK - The PTP Option Card Network Port has been set to Factory Default values<CR><LF>
Initialize the PTP Protocol to User-entered Values
Each time the user changes any PTP setting using F131, the user must enter this command for the
changes to take effect.
To initialize the PTP Protocol to user-entered values, use the following format:
F131 B<N> INIT<CR>
For example, enter:
F131 B4 INIT
F = ASCII character F
131 = Unit function number
<SP> = Space
B = ASCII letter to denote Option Bay number follows
<N> = Option Bay Number, 1 through 4.
SDN = Specify subdomain name command.
SUBDOMAIN = Specify one of the following:
_DFLT, _ALT1, _ALT2, _ALT3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom XLi IEEE 1588 and is the answer not in the manual?

Symmetricom XLi IEEE 1588 Specifications

General IconGeneral
BrandSymmetricom
ModelXLi IEEE 1588
CategoryClock
LanguageEnglish

Related product manuals