XLi IEEE 1588 Clock 167
997-01510-03, Rev. C, 12/12/2006
2
5
1
SSSSSSSSSSSS SSSSSSSSSS SSSSSSS S SSS S SSSSS S
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The time, in UTC, at which the trap was generated."
::= { systemAlarmData 2 }
alarmDataCodeOBJECT-TYPE
SYNTAX SystemAlarmType
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The code of the event that generated the alarm."
::= { systemAlarmData 3 }
alarmDataStatusDescriptorOBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"A description of the the XLi system at the time the alarm was
triggered. The format matches the output of the F73 command."
::= { systemAlarmData 4 }
alarmSystemNotification NOTIFICATION-TYPE
OBJECTS
{
alarmDataIpAddr,
alarmDataTimeStamp,
alarmDataCode,
alarmDataStatusDescriptor
}
STATUS current
DESCRIPTION
"A trap that indicates a change in system status. Refer to the list of
OBJECTS, above."
::= { xliTrap 1 }
configDataLatchClear OBJECT-TYPE
SYNTAX INTEGER {
latchClear (1)
}
MAX-ACCESS write-only
STATUS current
DESCRIPTION
"Setting to <latchClear> clears the latched fault indicators."
::= { systemFaultConfigData 1 }
configDataThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..99999)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time error threshold, in nanoseconds, at which the time error
fault is activated."

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom XLi IEEE 1588 and is the answer not in the manual?

Symmetricom XLi IEEE 1588 Specifications

General IconGeneral
BrandSymmetricom
ModelXLi IEEE 1588
CategoryClock
LanguageEnglish

Related product manuals