EasyManuals Logo

Symmetricom XLi IEEE 1588 User Manual

Symmetricom XLi IEEE 1588
216 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #179 background imageLoading...
Page #179 background image
XLi IEEE 1588 Clock 171
997-01510-03, Rev. C, 12/12/2006
2
5
1
SSSSSSSSSSSS SSSSSSSSSS SSSSSSS S SSS S SSSSS S
faultPrimaryRefClkOBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TRUE, if a primary reference clock fault occurred since the fault
latch was cleared."
::= { systemFaultHistory 3 }
faultSecondaryRefClk OBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TRUE, if a secondary reference clock lock fault occurred since the
fault latch was cleared."
::= { systemFaultHistory 4 }
faultIrig OBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TRUE, if an IRIG lock fault occurred since the fault
latch was cleared."
::= { systemFaultHistory 5 }
faultAuxRef OBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TRUE, if an auxiliary reference clock fault occurred since
the fault latch was cleared."
::= { systemFaultHistory 6 }
faultPrimaryPower OBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TRUE, if a primary power fault occurred since the fault
latch was cleared."
::= { systemFaultHistory 7 }
faultSecondaryPower OBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TRUE, if a secondary power fault occurred since the fault
latch was cleared."
::= { systemFaultHistory 8 }

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom XLi IEEE 1588 and is the answer not in the manual?

Symmetricom XLi IEEE 1588 Specifications

General IconGeneral
BrandSymmetricom
ModelXLi IEEE 1588
CategoryClock
LanguageEnglish

Related product manuals