XLi IEEE 1588 Clock 175
997-01510-03, Rev. C, 12/12/2006
2
5
1
SSSSSSSSSSSS SSSSSSSSSS SSSSSSS S SSS S SSSSS S
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Gives the current status of the primary power."
::= { systemStatusDetail 7 }
statusSecondaryPower OBJECT-TYPE
SYNTAX INTEGER {
ok (1),
fault (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Gives the current status of the secondary power."
::= { systemStatusDetail 8 }
statusRbOsc OBJECT-TYPE
SYNTAX INTEGER {
ok (1),
fault (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Gives the current status of the rubidium oscillator."
::= { systemStatusDetail 9 }
statusDac OBJECT-TYPE
SYNTAX INTEGER {
ok (1),
fault (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Gives the current status of the digital to analog convertor."
::= { systemStatusDetail 10 }
statusFirstTimeLock OBJECT-TYPE
SYNTAX INTEGER {
firstTimeLockedOnce (1),
firstTimeLockedOnceWithinTimeout (2),
firstTimeNotLocked (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Gives the current status of clock since power on.
(1)- indicates the clock has locked at least once since power on.
(2)- indicates the clock has locked since power on but is still within
the power on suppress timeout.
(3)- indicates the clock has not locked since power on."
::= { systemStatusDetail 11 }

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom XLi IEEE 1588 and is the answer not in the manual?

Symmetricom XLi IEEE 1588 Specifications

General IconGeneral
BrandSymmetricom
ModelXLi IEEE 1588
CategoryClock
LanguageEnglish

Related product manuals