Do you have a question about the TA Instruments TGA 2950 and is the answer not in the manual?
| Brand | TA Instruments |
|---|---|
| Model | TGA 2950 |
| Category | Measuring Instruments |
| Language | English |
Provides contact numbers for technical assistance, orders, and service for TA Instruments.
Addresses high voltage hazards and precautions for electrical procedures.
Discusses safe use of gases and handling of potentially hazardous chemicals.
Information on RCF insulation in furnace assemblies and handling procedures.
Need for furnace cleaning and venting harmful gases.
Advises on cooling down the furnace and avoiding contact with hot surfaces.
Warns about keeping fingers away from the moving furnace.
Explains the content and structure of each chapter and appendix.
Introduces the TGA 2950, its accessories, and specifications.
Covers unpacking, installation, and connecting the TGA to the system.
Details how to run TGA experiments and set up accessories.
Provides technical information and principles of TGA operation.
Explains maintenance, diagnostics, and troubleshooting procedures.
Lists TA Instruments offices for ordering and support.
Describes the High Resolution option, including installation and usage.
Provides instructions for operating the TGA Autosampler option.
Details installing and using the EGA furnace with the TGA 2950.
Overview of the TGA 2950 as a thermal analysis system.
Lists the five major components of the TGA 2950 instrument.
Details operator controls: instrument display and keypad.
Explains the HEATER and POWER switches for instrument operation.
Describes available accessories like Gas Switching and EGA Furnace.
Presents the technical specifications for the TGA 2950.
Instructions for unpacking and repackaging the TGA instrument.
Inspecting the system for damage and preparing for installation.
Guidelines for selecting an appropriate location for the instrument.
Details the process of filling the heat exchanger with coolant.
Instructions for connecting various cables and gas lines.
Steps for safely unpacking and installing the instrument's balance component.
Guide for installing the hang-down wires for sample and tare pans.
Instructions for adjusting the sample platform for proper operation.
Steps to start and safely shut down the TGA 2950 instrument.
General outline and prerequisites for TGA experiments.
Explains the need and types of calibration for accurate results.
Outlines the general steps for conducting a TGA experiment.
Details sample preparation, pan selection, and loading.
Describes automated and manual processes for taring the sample pan.
Instructions on using accessories like Air Cool, Purge Gas, and Gas Switching.
Steps to start, force start, stop, and unload samples.
Precautions and setup for running experiments in an oxygen-free environment.
Provides a detailed description of the TGA 2950 instrument.
Describes the Balance, Sample Loading Assembly, Furnace, Cabinet, and Heat Exchanger.
Explains the fundamental principles behind TGA operation.
Lists and explains the status codes displayed by the instrument.
Introduces the maintenance and diagnostic procedures covered.
Outlines regular maintenance tasks for the instrument.
Instructions for cleaning the furnace housing and standard furnace.
Procedures for maintaining coolant and refilling the water reservoir.
Procedures for replacing the thermocouple and furnace.
Guidance on troubleshooting power-related issues including fuses and failures.
Describes instrument test functions and the confidence test.
Lists available replacement parts for the TGA 2950.
Provides contact details for TA Instruments offices globally.
Describes benefits, installation, and background of the Hi-Res TGA option.
Details Hi-Res techniques, ramp segments, and examples.
Discusses sample quantity, surface area, bubble formation, and thermocouple placement.
How Hi-Res TGA affects data analysis, derivative plots, and smoothing.
Guides on adjusting heating rate, resolution, and sensitivity settings.
Details on using abort segments and stepwise isothermal heating.
Presents example scans for various materials and lists references.
Introduction to the Auto TGA accessory and basic setup.
Steps for preparing samples and taring pans for the autosampler.
Procedures for automatic taring and loading of samples.
Guide to setting up experiments, manual operation, and tracking status.
Options for stopping an Auto TGA run in progress.
Introduction and specifications for the Evolved Gas Analysis (EGA) Furnace.
Covers installation, first-time setup, and removal procedures for the EGA furnace.
Instructions for connecting a spectrometer to the EGA furnace for gas analysis.
Guidance on using and cleaning the EGA furnace and its quartz tube.