TP9100 Service Manual Frequency Synthesizer Fault Finding 205
© Tait Electronics Limited May 2005
9.8 Power Supply for FCL
Fault-Diagnosis
Stages
Indications of a fault in the FCL will have been revealed by the initial checks
in “Initial Checks” on page 160 and the PLL checks in “Phase-Locked
Loop” on page 170. In the latter case a fault with the reference frequency
input from the FCL to the PLL will imply that the FCL is suspect. Fault
diagnosis of the FCL is divided into four stages:
check power supply
check VCXO and VCTCXO outputs
check signals at TP501 and TP502
check VCXO and CODEC circuitry
The checking of the power supply is given in this section in Tas k 3 4
below.
The remaining three stages are covered in “VCXO and VCTCXO
Outputs to “VCXO and CODEC Circuitry” on page 214 respectively.
The test and measurement points for diagnosing faults in the FCL are
summarized in Figure 9.18.