Page 14 of 32 IU_TechMaster_02_eng
Press to confirm. LCD will display current values for time delay
and open window.
Press to exit or to set new values.
Enter new values for Time Delay and Open Window and press
to confirm. LCD will display the message:
Accepted values are: 00÷99min for Time Delay and 01÷19min for Open Window.
To set a lower Time Delay value than the currently set on the lock, the lock must be opened.
If the lock is closed it won’t accept the new entered values. Open the lock and then set new
Time Delay values.
Depending on lock configuration this menu could not be available
Power up TechMaster and access the Manager Menu.
Press two times. LCD will display the message:
2.3.1. Variable Time Delay - Add
Use this function to add Variable Time Delay values.
Power up TechMaster and access the Variable Time Delay menu.
Press . LCD will display the message:
Press . LCD will display the current day of the week.
Enter values for starting time and ending time in which Variable Time
Delay will be active and then enter the values of Variable Time Delay.
Press to confirm. LCD will display the next day of the week, and
will propose the same values. Press to confirm or to skip
and change day.
At the end of the week LCD will display the message:
END OF LIST
EXIT AND SAVE? !