Page 20 of 32 IU_TechMaster_02_eng
Use this function to start up the Time Lock immediately.
Power up TechMaster and access the Time Menu.
Press . LCD will display the message:
USER CODE
X X ā X X X X X X
If you hold the Manager code press . LCD will display the
message:
Enter the User code (or enter the Manager code). LCD will display the
message:
Press . LCD will display the message:
Press . If Time lock period is programmed, LCD will display the
next Time Lock opening period:
CLOSED UNTIL:
14/09 08:00
If you want to enter different values enter new values for time and
date (max. 2 weeks), then press to confirm.
CLOSED UNTIL:
DD/MM hh:mm
If no time lock period is programmed it will be only possible to enter
new values: enter new values for time and date (max. 2 weeks), then
press to confirm.
CLOSED UNTIL:
DD/MM hh:mm
Press and then press five times. LCD will display the
message:
CONFIGURATION
X X X X X X
Enter Configuration code (default code 5-0-5-0-5-0).