EasyManua.ls Logo

Technica Engineering CM CAN Combo - Page 64

Technica Engineering CM CAN Combo
70 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CM CAN Combo User Manual
64
Counter
UINT16
Counter is incremented for each TECMP frame sent from a Capture
Module. The counter starts again from 0x0000 when reaching the
maximum value 0xFFFF. If a Capture Module has several physical
interfaces to the sink (Ethernet links), a separate counter is
implemented on each interface. The CM_ID field is the same for all
interfaces in this case.
Version
UINT8
Used version of the TECMP protocol; This UINT8 uniquely identifies
the version. Technica will try to sync the versions with versions of
PLP to establish compatibility.
TECMP_Function
UINT8
Description of the payload function, whether status, config or bus
data
IVN_Type
UINT16
Description of the Type of Source Data (e.g., CAN, LIN, Flexray,
Ethernet, Undefined, Voltage, Current, ...). These types are
preconfigured and fixed.
Reserved
UINT16
Reserved, pre-filled with 0x0000
TECMP_Signals
UINT16
0b0000 0000 0000 0001 EoS (End of Segment; used to signal a last
segment of segmented information.) 0b0000 0000 0000 0010 SoS
(Start of Segment: used to signal a first segment of segmented
information
Note: For single segment transmitted in a TECMP frame, the
TECMP_Signals EoS and SoS are always set to ‘1’. 0b0000 0000
0000 0100 SPY (SPY flag can be used to trigger additional actions
on the sink.) Note: For messages from recording on-board
communication, the value for the flag is always '1'.) 0b0000 0000
0000 1000 Multi-Frame (a Capture Module that can send multiple
TECMP_Channels in a TECMP frame must set this flag) 0b0000
0000 0001 0000 reserved
0b0000 0000 0010 0000 - reserved
0b0000 0000 0100 0000 reserved
0b0000 0000 1000 0000 reserved
0b0000 0001 0000 0000 reserved
0b0000 0010 0000 0000 reserved
0b0000 0100 0000 0000 reserved
0b0000 1000 0000 0000 reserved
0b0001 0000 0000 0000 reserved
0b0010 0000 0000 0000 reserved
0b0100 0000 0000 0000 reserved
0b1000 0000 0000 0000 Capture Module overflow (Module has lost
data)
TECMP_Channel
UINT32
ID that uniquely identifies the log data / bus / link on the IVN.
Timestamp
UINT64
Timestamp is the time in past 1ns since Thursday, January 1, 1970,
00:00 UTC. The resolution is 1ns.
Bit 63:
1: time is asynchronous, synchronization with the timing master
failed
0: time is synchronous, synchronization with the timing master
successful
Bit 62: Reserved

Table of Contents

Related product manuals