8.2.Control unit
To ensure your machine's correct operation, install the control unit in a ventilated area where the temperature is
between 0° C and 45° C.
We recommend a minimum distance of 300mm (12in) at the rear of the control unit to avoid stressing the various
connected cables and to allow sufficient access for potential interventions.
Illustration 36: Unobstructed zone at the rear of the control unit
Integration area for control box must have a minimum volume of 30L (30 dm
3
1 cu ft).
8.2.1. Electrical installation
The electrical installation of your equipment must be carried out in compliance with accepted trade practices and
local regulations. You must use the power cable that came with your equipment to connect it to the network.
The control unit requires a 90-240 V mono ~ 3.4A 50/60 Hz power supply.
The control unit is equipped with a 5A internal fuse, delayed T-type with high H breaking capacity (ceramic),
250VAC, UL: 115 V - 300 VDC, size 5 x 20mm (e.g.: 0001.2511 Schurter 0001.2511, UL E41599, VDE 40014395).
Th
Th
Th
Th
Th
The power outlet socket should be installed near the equipment and must be easily accessible.
The power supply upstream from the control
unit
must have a maximum 16A protection, of a 30mA residual-
current circuit breaker and must be grounded.
The building's electrical system must provide protection from ground faults.