Programming of zones and programs Installer Manual - TP8-96 VIDEO
2-18
WIRELESS SECTION
Permits enabling and configuration of the supervision and
antimasking functions:
z Supervision
The supervision alarm is released if one of the wireless
devices omits the test transmission (and any alarm
signaling) for a period of time superior to the supervision
interval (see time parameters). The supervision alarm is
stored in the event buffer.
Signaling
If enabled, in case of supervision alarm, on the console
is signaled trouble and possible programmed outputs
(supervisory boards and logic outputs) signal
supervision alarm.
Sirens
If enabled, in case of supervision alarm, the sirens are
activated for the programmed tamper alarm time (see
time parameters).
z Antimasking
The antimasking alarm is released if the wireless receiver-
transmitter connected to the control panel detects a
jamming signal with the same frequency as the
transmission frequency of the wireless detectors, constant
for a period of time superior to the antimasking filter (see
time parameters). The antimasking alarm is stored in the
event buffer.
Signaling
If enabled, in case of antimasking alarm, on the console
is signaled trouble and possible programmed outputs
(supervisory boards and logic outputs) signal
antimasking alarm.
Sirens
If enabled, in case of antimasking alarm, the sirens are
activated for the programmed tamper alarm time(see
time parameters).
REPORT VOCAL MESSAGES
Permits enabling of the voice report by the console for all system
status and alarm signaling.
ALARM OUTPUTS
Permits the association of the programs to the siren output and
programmable logic output to be activated in case of alarm. Every
program can pilot independently:
z Logic siren 1 to 8
The logic siren is not bound to a physical siren but is activated
under determined conditions. Only in the programming section
of the outputs the logic siren is associated to a siren (indoor or
outdoor) output of one of the connected modules .
To select the logic siren click on the arrow next to the
inscription Siren 1 and scroll the siren list (1 to 8).
z Programmable logic output PGM
To associate the output to the programs check the item
beneath the program number.
WARNING
If the voice report is enabled it is recommended to disable the buzzer of the consoles in order to avoid
the superimposition of signaling.
To disable the buzzer of the consoles, use the dip-switch (dip 10) on the electronic boards of the
consoles.