4-120
03-11 Relay (R1A-R1C) output
03-12 Relay (R2A-R2C) output
Range
【0】: During Running
【1】: Fault Contact Output
【2】: Frequency Agree
【3】: Setting Frequency Agree (03-13 ± 03-14)
【4】: Frequency Detection 1 (≧ 03-13, hysteresis range is the setting value of
03-14)
【5】: Frequency Detection 2 (≦03-13, hysteresis range is the setting value of
03-14)
【6】: Automatic Restart
【7】: Momentary AC Power Loss
【8】: Rapid Stop
【9】: Base Block
【10】: Motor Overload Protection (OL1)
【11】: Drive Overload Protection (OL2)
【12】: Over Torque Threshold Level (OL3)
【13】: Preset Output Current Reached
【14】: Brake Control
【15】: PID Feedback Signal Loss
【16】: Single Pre-set Count (03-22~03-23)
【17】: Dual Pre-set Count (03-22~03-23)
【18】: PLC Status Indicator (00-02)
【19】: PLC Control
【20】: Zero Speed
【30】: Motor 2 Selection
【37】: Detection Output of PID Feedback Loss
【54】: Turn On Short-Circuit Braking
【55】: Low Current Detection
【59】: OH Detection
Figure 4.3.25 Multi-function digital output and related parameters