4-121
Table 4.3.29 Function table of multi-function digital output
Value
Function
Contents
Control mode
Name LCD display V/F SLV
PM
SLV
0 During Running Running ON:Dring running (Run command is ON) O O O
1 Fault Contact Output Fault
ON:Fault contact output (except CF00 and
CF01)
O O O
2 Frequency Agree Freq. Agree
ON:Frequency agree (frequency agree width
detection is set by 03-14 )
O O O
3
Setting Frequency
Agree (03-13 ±
03-14)
Setting Freq Agree
ON:Output frequency = allowed frequency
detection level (03-13) ± frequency
bandwidth (03-14)
O O O
4
Frequency Detection
1 (≧ 03-13, hysteresis
range is the setting
value of 03-14)
Freq. Detect 1
ON:Output frequency > 03-13, Hysteresis
range is 03-14
O O O
5
Frequency Detection
2 (≦03-13, hysteresis
range is the setting
value of 03-14)
Freq. Detect 2
OFF:Output frequency > 03-13, Hysteresis
range is 03-14
O O O
6 Automatic Restart Auto Restart ON:the period of automatic restart O O O
7
Momentary AC
Power Loss
Invalid Do Func. Reserved O O O
8 Rapid Stop Invalid Do Func. Reserved O O O
9 Base Block Baseblock ON:During Baseblock O O O
10
Motor Overload
Protection (OL1)
Invalid Do Func. Reserved O O O
11
Drive Overload
Protection (OL2)
Invalid Do Func. Reserved O O O
12
Over Torque
Threshold Level (OL3)
Over Torque ON:Over torque detection is ON O O O
13
Preset Output
Current Reached
Currebt Agree ON:When output current > 03-15 is ON O O O
14 Brake Control Invalid Do Func.
ON:Mechanical braking release frequency
OFF:Mechanical braking run frequency
O O O
15
PID Feedback Signal
Loss
Invalid Do Func. Reserved O O O
16
Single Pre-set Count
(03-22~03-23)
Invalid Do Func. Reserved O O O
17
Dual Pre-set Count
(03-22~03-23)
Invalid Do Func. Reserved O O O
18
PLC Status Indicator
(00-02)
PLC statement
ON:When 00-02 is set to 3
(PLC operation command source)
O O O
19 PLC Control Control From PLC ON:Control from PLC O O O
20 Zero Speed Zero Speed
ON:Output frequency < Minimum output
frequency (Fmin)
O O O
21 Reserved Reserved Reserved - - -
22 Reserved Reserved Reserved - - -