4-130
03-27
Pulse Frequency Selection (S3)
Range
50~25000Hz
03- 28 Pulse Frequency Gain
Range
0.0~1000.0】%
03- 30 Pulse Input Selection
Range
【0】:General Pulse input
【1】:PWM
There are two ways for pulse input selection:
(1) General pulse input:
PI=Cutoff frequency divided by pulse input scale set by 03-27, corresponding to the maximum
output frequency of motor 1 (01-02).
(2) PWM:It is required to input the correct frequency
PWM= Time of negative edge pulse divided by the time period of pulse, corresponding to the
maximum output frequency of motor 1 (01-02).
Note:
Deviation of pulse time period in PWM is ±12.5%. If it is over the deviation range, pulse input is not
active.
Diagram for pulse input selection:
Example of pulse input setting:
1. Normal pulse input (Both NPN/PNP connection can be used)
03-30=0
00-05=7 (Main Frequency Command Source Selection)
03-27=200Hz (Pulse Frequency)
03-28=100.0~1000% (Pulse Input Gain)
When 03-27 with different value, the ouput frequency of display will be different.
03-27=100Hz, 00-12=60.00, 03-28=100.0, keypad display will be 30.00Hz
03-27=200Hz, 00-12=60.00, 03-28=100.0, keypad display will be 60.00Hz
03-27=100Hz, 00-12=60.00, 03-28=200.0, keypad display will be 60.00Hz
2. PWM Input (NPN connection only)
03-30=1
00-05=7 (Main Frequency Command Source Selection)

Table of Contents