Appendix A: Specications
Table 2: Input Specications (cont.)
Characteris
tic
Description
Maximum Input Voltage
At front panel connector, 300 V RMS, Installation Category II; derate at 20 dB/decade above 100 kHz to 13 V peak AC at 3 MHz and
above.
Based upon sinusoidal or DC input signal. Maximum viewable signal while DC coupled is ±50 V offset ±5 V/division at 4 divisions, or
70 V. AC coupling allows measuring signals on a DC level up to 300 V. For non-sinusoidal waveforms, peak value must be less than
450 V. Excu
rsion above 300 V should be less than 100 ms duration and the duty factor is limited to < 44%. RMS signal level must be
limited to 300 V. If these values are exceeded, damage to the instrument may result.
Common Mod
e Rejection
Ratio (CMRR), typical
With the sa
me signal applied to each channel, CMRR is the ratio of the acquired signal amplitude to the amplitude of the MATH
difference waveform, either (Ch1 - Ch2), (Ch2 - Ch1), (Ch3 - Ch4) or (Ch4 - Ch3).
TDS1012C-EDU, TDS2012C, TDS2014C, TDS2022C, TDS2024C: 100:1 at 60 Hz, reducing to 10:1 with 50 MHz sine wave, with
equal Vol
ts/division and Coupling settings on each channel.
TDS1001C-EDU, TDS1002C-EDU, TDS2001C, TDS2002C, TDS2004C: 100:1 at 60 Hz, reducing to 20:1 with a sine wave with
frequency equal to ½ the -3 dB bandwidth and with equal Volts/division and Coupling settings on each channel.
The ratio of the level of a signal input into one channel to that of the same signal present in another channel due to stray coupling.
TDS1001
C-EDU,
TDS2001C
TDS1002
C-EDU,
TDS2002C, 2004C
TDS1012
C-EDU, TDS2012C,
2014C
TDS2022
C, 2024C
Crosstalk (Channel Isolation)
>100:1 with 20 MHz sine
wave and
with equal V/div
settings on each channel
: >100:1 with 30 MHz sine
wave and
with equal V/div
settings on each channel
>100:1 with 50 MHz sine
wave and
with equal V/div
settings on each channel
>100:1 with 100 MHz s ine
wave and
with equal V/div
settings on each channel
Table 3: Vertical Specications
Characteristic Description
Numbe
r of Digitized Bits
8bits
except at 2 mV/div
The number of bits in each binary word that results from the A/D converting each analog value value to a digitized value. (IEEE
standard 1057, Section 2.2.1)
Disp
layed vertically with 25 digitalization levels per division, 10 divisions dynamic range.
2 mV/division setting is generated by digital multiplication and the resolution is reduced. Given 100 levels available, the resolution is
>6.5 bits.
Sensitivity Range 2 mV/Div to 5 V/Div in 1-2-5 sequence with probe attenuation set to 1X
The
position ranges are as follows
Volts/Div Setting
Position Range
2 mV/div to 200 mV/div
±1
.8 V
Vertical Position Ranges
>2
00 mV/div to 5 V/div
±45 V
108 TDS2000C and TDS1000C-EDU Series Oscilloscope User Manual

Table of Contents

Other manuals for Tektronix TDS2000C series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TDS2000C series and is the answer not in the manual?

Tektronix TDS2000C series Specifications

General IconGeneral
BrandTektronix
ModelTDS2000C series
CategoryTest Equipment
LanguageEnglish

Related product manuals