TTE Combo Communication ModuleInstallation and Programming Manual
37
SIA
Code
Event Code Description Address Field
NA No Activity
There has been no zone activity for a programmed
amount of time.
Zone number
NF
Forced Perimeter Arm
Some zones/points not ready.
Area number
NL
Perimeter Armed
An area has been perimeter armed.
Area number
OA
Automatic Opening
System has disarmed automatically
Area number
OC
Cancel Report
Untyped zone cancel.
User number
OG
Open Area
System has been partially disarmed.
Area number
OI Fail to Open
An area has not been armed at the end of the opening
window.
Area number
OJ
Late Open
An area was disarmed after the opening window.
User number
OK
Early Open
An area was disarmed before the opening window.
User number
OP
Opening Report
Account was disarmed.
User number
OQ
Remote Opening
The system was disarmed from a remote location.
User number
OR
Disarm From Alarm
Account in alarm was reset/disarmed.
User number
OS
Opening Keyswitch
Account has been disarmed by keyswitch.
Zone or point
OT
Late To Close
System was not armed on time.
User number
OZ
Point Opening
A point, rather than a full area or account, disarmed.
Zone or point
PA
Panic Alarm
Emergency assistance request, manually activated.
Zone or point
PB
Panic Bypass
Panic zone has been bypassed.
Zone or point
PH
Panic Alarm Restore
Alarm condition eliminated.
Zone or point
PJ
Panic Trouble Restore
Trouble condition eliminated.
Zone or point
PR
Panic Restoral
Alarm/trouble condition has been eliminated.
Zone or point
PS
Panic Supervisory
Unsafe system condition exists.
Zone or point
PT
Panic Trouble
Zone disabled by fault.
Zone or point
PU
Panic Unbypass
Panic zone bypass has been removed.
Zone or point
QA
Emergency Alarm
Emergency assistance request.
Zone or point
QB
Emergency Bypass
Zone has been bypassed.
Zone or point
QH
Emergency Alarm Restore
Alarm condition has been eliminated.
Zone or point
QJ
Emergency Trouble Restore
Trouble condition has been eliminated.
Zone or point
QR
Emergency Restoral
Alarm/trouble condition has been eliminated.
Zone or point
QS
Emergency Supervisory
Unsafe system condition exists.
Zone or point
QT
Emergency Trouble
Zone disabled by fault.
Zone or point
QU
Emergency Unbypass
Bypass has been removed.
Zone or point
RA
Remote Programmer Call
Failed
Transmitter failed to communicate with the remote
programmer.
Unused
RB
Remote Program Begin
Remote programming session initiated.
Unused
RC
Relay Close
A relay has energized.
Relay number
RD
Remote Program Denied
Access passcode incorrect.
Unused
RN
Remote Reset
A TRANSMITTER was reset via a remote programmer.
Unused
RO
Relay Open
A relay has de-energized.
Relay number
RP
Automatic Test
Automatic communication test report.
Unused
RR
Power Up
System lost power, is now restored.
Unused
RS
Remote Program Success
Remote programming successful.
Unused
RT
Data Lost
Dialer data lost, transmission error.
Line number
RU
Remote Program Fail
Remote programming unsuccessful.
Unused